Style guide

Readability is part of the numerical interface

Thermodynamic code is easier to review when readers can connect each quantity to an equation, its units, and its independent variables. Prefer descriptive names for algorithms and conventional symbols for equations; define the latter where they first appear. Use three-space indentation, implicit none, explicit imports where practical, and named closing statements.

One variable per declaration

In new code and pedagogical examples, put one variable on each declaration line, including scalars, arrays, loop indices, and derived-type components. This leaves room for a useful unit or physical meaning and makes changes easy to review. For example:

use yaeos, only: pr
implicit none

real(pr), intent(in) :: n(:) !! Component mole amounts [mol]
real(pr), intent(in) :: V    !! Total volume [L], not molar volume
real(pr), intent(in) :: T    !! Temperature [K]
real(pr), intent(out), optional :: ArV !! (dAr/dV) at fixed n,T [bar]
real(pr), allocatable :: kij(:, :) !! Dimensionless interaction matrix
integer :: i !! Component index
integer :: j !! Component index

This is a declaration fragment inside a procedure, not a standalone program. Do not group these as real(pr) :: n(2), V, T or integer :: i, j. The repository guide included below contains older grouped-array examples; use the one-variable convention for new declarations rather than copying those groups. Do not reformat unrelated source as part of a small fix.

The same rule applies to derived-type components and to dummy arguments:

type :: MyModel
   real(pr), allocatable :: ac(:) !! Pure-component attraction parameters [bar L^2/mol^2]
   real(pr), allocatable :: b(:)  !! Pure-component covolumes [L/mol]
contains
   procedure :: residual_helmholtz => my_ar !! Evaluate A^r and its derivatives
   procedure :: get_v0 => my_v0 !! Volume scale for the liquid root [L]
end type MyModel

A reader comparing your code with the Fortran core guide of the developer handbook should find the same conventions in both.

Comments should add information: “total volume [L]” is useful; “variable V” is not. Array comments should explain index order when it matters, especially for interaction matrices and Hessians.

Precision, units, and derivative names

  • Import pr and use real(pr) and kind-qualified real literals such as 1.0_pr. Import R instead of hard-coding a gas constant with different units.
  • Use the library’s bar, L, K, mol basis. An extensive energy is in bar L, not bar L/mol. State any conversions at external data boundaries.
  • Use thermodynamic input order n, V, T or n, P, T. Name optional outputs at call sites when positional lists would obscure the derivative requested.
  • Energy derivatives use ArV, ArT, ArTV, ArV2, Arn, Arn2, etc.; general properties use names such as dPdV. State what stays fixed rather than relying on a short variable name alone.
  • The shape of a mole gradient is size(n); the mole Hessian has two component indices. A normalized composition derivative is not a mole derivative.

Match contracts rather than improving them accidentally

Specify intent for procedure arguments when defining a new interface. When overriding an existing deferred binding, however, match its declared attributes exactly. The hyperdual Ar passed-object dummy has no intent; adding one can break the override. Analytic residual_helmholtz, hyperdual Ar, and Tapenade ar are different contracts, despite related names.

Guard optional outputs with present. Calculate shared working quantities in local variables, not in an optional output that a caller may omit. Every requested output must be assigned regardless of which others are present. Document required initialization, array sizes, admissible domains, and any assumptions such as symmetric parameter matrices.

Explain numerical choices and test them

Explain why a bound, step size, or tolerance is appropriate and give its units or scale. Avoid unexplained “magic” constants. Test ordinary states before edge cases, then add dilute, pure-component, and near-boundary cases relevant to the model. Do not turn a failed convergence check into a successful result by silently replacing nonfinite values.

For documentation, pair a mathematical definition with one minimal call and an interpretation of its output. Preserve existing examples and references when expanding a page. Compile runnable snippets against the current interface and label sketches honestly. See the contributing workflow for the build, test, and FORD preview steps, and the developer handbook for the surrounding codebase.

In guide text, link to the generated page, for example [Mixing rules](../usage/eos/cubics/mixing.html), rather than a local .md file. Resolve the path relative to the rendered page, and check any #anchor against the generated HTML. FORD does not automatically rewrite ordinary Markdown links from .md to .html.

This differs from FORD’s ordered_subpage front matter and include directives: those identify source files and must retain their .md filenames. An explicitly labelled external GitHub source-file link can also legitimately end in .md; it is not an internal documentation navigation link.

Repository-wide style reference

yaeos Style Guide

Adopting a consistent style can improve code legibility through the choice of good naming conventions. In addition, style checks will be run during CI to flag any severe non-conformance. This allows code review discussions to focus on semantics and substance rather than pedantry. Consistent whitespace usage, and not polluting line endings with trailing white space makes git diffs considerably more legible. This style guide is a living document and proposed changes may be adopted after discussing them and coming to a consensus.

Use (modern) standard Fortran

  • Do not use obsolescent or deleted language features E.g., common, pause, entry, arithmetic if and computed goto
  • Do not use vendor extensions in the form of non-standard syntax and vendor supplied intrinsic procedures E.g., real*8 or etime(), use real(pr)

Naming of variables and constructs

  • Variable and procedure names, as well as Fortran keywords, should be written in lowercase
  • All constants (like the R gas constant) should be upper case
  • All variables should be in lowercase unless they are represented in uppercase in the bibliography. for example, the molar volume would be v and the total volume would be V.
  • In the case of derivatives, for general properties they should be written as dXdy for first derivatives and dXdyz or dXdy2 for second order derivatives. The only exception is with energetic properties, like Ar, where derivatives are written like ArV, ArVn, etc.
  • All thermodynamic variables that are input of a subroutine/function should have the order:
  • n, V, T
  • n, P, T
  • Variable and procedure names should be made up of one or more full words separated by an underscore, for example has_failed is preferred over hasfailed
  • Where conventional and appropriate shortening of a word is used then the underscore may be omitted, for example linspace is preferred over lin_space
  • For derived types use CamelCase, like ArModel

File naming conventions

  • Source files should contain at most one program, module, or submodule
  • The filename should match the program or module name and have the file extension .f90 or .F90 if preprocessing is required
  • module names should include its subdirectory, using yaeos__ for the parent src directory. For example the module in src/equilibria/flash.f90 is named yaeos__equilibria_flash. If the module name is longer than the accepted number of columns of the compiler, it is possible to simplify to just initials of each word: yaeos__p_e_f
  • If the interface and implementation is split using submodules the implementation submodule file should have the same name as the interface (parent) module but end in _implementation E.g., string_class.f90 and string_class_implementation.f90
  • Tests should be added in the test subdirectory and have the same name as the module they are testing with the test_ prefix added E.g., string_class.f90 and test/test_string_class.f90

Indentation & whitespace

By setting and following a convention for indentation and whitespace, code reviews and git-diffs can focus on the semantics of the proposed changes rather than style and formatting.

We recommend ~~enforce~~ the use of findent to format your files.

  • The body of every Fortran construct should be indented by three (3) spaces
  • Line length should be limited to 80 characters and must not exceed 132
  • Do not use Tab characters for indentation
  • Remove trailing white space before committing code

Attributes

  • Always specify intent for dummy arguments.
  • Don’t use dimension attribute to declare arrays because it is more verbose. Use this:
    real, allocatable :: a(:), b(:,:)
    instead of:
    real, dimension(:), allocatable :: a
    real, dimension(:,:), allocatable :: b
    When defining many arrays of the same dimension, dimension can be used as an exception if it makes the code less verbose.
  • If the optional attribute is used to declare a dummy argument, it should follow the intent attribute.

End block closing statements

Fortran allows certain block constructs or scopes to include the name of the program unit in the end statement. The convention adopted herein is to include procedure names, module names and program names in the end statement

Document public API code with FORD

Documentation strings should be provided for all public and protected entities and their arguments or parameters. This is currently accomplished using the FORD tool. For help writing FORD style documentation please see the FORD wiki. The following sections are most relevant for contributing new code:

To write the “spec” (specification) for a new proposal, please place it in the FORD “pages” directory at doc/page/. To get help please see the “Writing Pages” and “Writing Documentation” pages on the FORD wiki.